HP-80 Hydronic Expansion Tank

80-Liter (20 Gallon) Tank for Hydronic Heating & Cooling Systems| Aquasky HYDRO-PLUS Series | Made in Taiwan

HP-80 is designed specifically to absorb expanded fluid in closed-loop residential or commercial hydronic heating and cooling systems, effectively regulating pressure buildup and ensuring system safety.

HP-80 has a total volume of 80 liters (20 gallons). The tank is designed for a maximum operating pressure of 10 bar (150 psi) and a maximum operating temperature of 130 °C (266 °F). It is factory pre-charged to 1 bar (15 psi) for stable system performance and is fully compatible with propylene glycol mixture concentrations of up to 50%.

With a diameter of 43.2 cm (17.0 inches) and a height of 70.0 cm (27.6 inches), this stand-model tank comes with a heavy-duty base, providing massive expansion absorption for demanding commercial and large residential climate-control systems.

HP-80

Product Overview

The HP-80 is an 80-liter (20 gallon) hydronic expansion tank engineered specifically for closed-loop hydronic heating and cooling systems. As the fluid in your climate-control system changes temperature, it expands and contracts; the HP-80 safely absorbs this expanded fluid volume, effectively controlling the excessive pressure generated inside the system and preventing potential hazards.

Constructed from robust sheet steel tanks compliant with IAPMO and EN standards, the HP-80 is welded according to strict ASME & EN procedures by certified welders, ensuring long-lasting durability and safety. Utilizing a specialized, high-temperature-resistant EPDM rubber diaphragm, it ensures exceptionally reliable operation. To guarantee supreme robustness, every single Hydro-Plus model undergoes rigorous hydraulic testing at a pressure 1.5 times higher than the design pressure.

Manufactured with premium materials, Aquasky HYDRO-PLUS tanks are the ultimate safety choice for your hydronic heating system, delivering dependable performance and peace of mind.     

Certification

Specifications and Technical Data

Parameter Value
Model Number HP-80
Total Tank Volume 80 liters / 20 gallons
Diameter 43.2 cm / 17.0 inches
Height 70.0 cm / 27.6 inches
Net Weight (NW) 12.7 kg / 28.0 lbs 
Gross Weight (GW) 14.6 kg / 32.2 lbs 
Shipping Volume 5.00 CUF 
Max. Operating Temperature 130°C / 266°F
Factory Pre-charge 1 bar | 15 psi
Max. Operating Pressure 10 bar | 150 psi
Connection 1" Cacbon Steel / Stainless Steel
Diaphragm Material High-temperature resistance EPDM Rubber
Tank Body Shell Cold Rolled Carbon Steel
External Coating Gray Paint
Air Nozzle Protection Brass cap with internal O-ring
Pre-charge Gas 100% Nitrogen

Key Features & Design Advantages

  • High-temperature resistance EPDM rubber diaphragm engineered specifically to withstand rigorous and frequent hydronic heating and cooling cycles
  • Cold rolled carbon steel shell welded according to exacting ASME & EN procedures by certified welders for ultimate durability
  • 1.5x hydraulic pressure tested to ensure absolute safety and prevent leaks under extreme operational conditions
  • Brass cap with an internal O-ring to protect the air nozzle and guarantee absolutely zero air loss from the air-vent
  • Compatible with up to 50% propylene glycol mixtures, making it highly versatile for various climates, anti-freeze setups, and commercial chillers
  • Protective gray paint coating (Pantone 428C) for a professional aesthetic and long-term environmental resistance
  • 100% made in Taiwan
Materials & Design Advantages

How the HYDRO-PLUS Pressure Tank Works

In closed hydronic heating and cooling systems, fluid volume changes drastically as the temperature rises and falls. The HP-80 safely absorbs this expanded fluid using a sealed, compressible air cushion space. It stores the fluid securely against the high-temperature EPDM rubber diaphragm, while the air chamber compresses to accommodate the volume change. This mechanism seamlessly controls excessive pressure, protects valves and piping, and maintains safe system parameters without venting fluid.

Key benefits

  • Absorbs excess fluid volume during thermal cycles. 
  • Protects system components (boilers, piping, valves) from damaging high pressure. 
  • Delivers a safe and stable system for residential and commercial hydronic applications. 
  • Guarantees peace of mind through strict manufacturing standards and a 1.5x design pressure hydraulic test.

Typical Applications 

  • High-capacity closed-loop residential and commercial hydronic heating systems
  • Large-scale hydronic cooling installations
  • Non-potable water applications (compatible with up to 50% propylene glycol mixtures)

Frequently Asked Question (FAQ)

Q1 : Is the HP-80 a good fit for a commercial heating system?

A: Yes, the HP-80 is an excellent choice for absorbing expanded fluid in both residential and commercial hydronic heating systems, offering a robust 20-gallon capacity.

Q2 : Can a tank this large still handle the same extreme heat as the smaller models?

A: Yes, every tank in the series is rated to handle a maximum operating temperature of 130°C (266°F).

Q3 : How heavy is this model if I need to move it down some stairs?

A : The HP-80 has a net weight of 28.0 lbs before it is filled with water.